Heavyweight launch - standard sample of ethylene oxide aqueous solution

Date :2021-04-28 19:25 Click:

This product is suitable for the detection and control of residual solvents of ethylene oxide in pharmaceutical packaging materials, food packaging materials, medical surgical masks, medical protective masks, and medical disposable protective clothing. It is consistent with GB19082-2009 "Technical Requirements for Medical Disposable Protective Clothing", GB14233.1-2008 "Inspection Methods for Medical Infusion, Blood Transfusion, and Injection Equipment Part 1: Chemical Analysis Methods", GB19083-2010 "Technical Requirements for Medical Protective Masks" YBB00242005-2015 "Determination of Ethylene Oxide Residue" and YY0469-2011 "Medical Surgical Mask" standards are used in conjunction with the detection of ethylene oxide residue. They can also be used for quantity traceability or as standard reserve solutions, and can be gradually diluted to prepare various working standard solutions.


Our company has successfully developed a standard sample of ethylene oxide aqueous solution. Ethylene oxide sterilization is not only suitable for the pharmaceutical, food packaging materials industry, medical surgical masks, medical protective masks, and medical disposable protective clothing to achieve sterilization effects. Its uses are much wider than we imagine, especially in the medical field: it is as large as the disinfection of precision instruments and surgical instruments that we usually know, As small as our infusion tubes and needles. Ethylene oxide is a gas that can achieve disinfection without blind spots, which is thorough compared to other disinfection methods such as radiation, and has reasonable economic benefits. Ethylene oxide is used for sterilization in various industries in most countries around the world. Especially in this epidemic, a large number of medical surgical masks, medical protective masks, and disposable medical protective clothing are in demand. While paying attention to protection needs, ethylene oxide disinfection has also received high attention.


The safety of ethylene oxide gas sterilization has been fully recognized, as it can kill all bacterial spores, but it is also a toxic gas to the human body. The residual solvent of ethylene oxide in pharmaceutical packaging materials, food packaging materials, medical surgical masks, medical protective masks, and medical disposable protective clothing refers to the residual solvent of ethylene oxide used during the sterilization process but not completely removed during the sterilization process.


Due to their special use in direct contact with drugs and food, drug packaging materials and food packaging materials must strictly control and supervise the residue of ethylene oxide substances that pose a threat to human health during their production process, in order to assist in the development, standardization, and accuracy improvement of safety testing methods for residual solvents of ethylene oxide. Standard samples suitable for the determination of residual ethylene oxide after sterilization of medicinal, food packaging materials, surgical masks, protective masks, and disposable protective clothing.